MODEL |
DX100KVA |
DX120KVA |
DX125KVA |
DX150KVA |
DX160KVA |
190KVA |
200KVA |
Rated Power |
80KW |
96KW |
100KW |
120KW |
128KW |
150KW |
160KW |
Peak Power(20ms) |
240KVA |
288KVA |
300KVA |
360KVA |
384KVA |
450KVA |
480KVA |
Start Motor |
40HP |
50HP |
50HP |
60HP |
60HP |
80HP |
80HP |
Battery Voltage |
384VDC |
Size(L*W*Hmm) |
875*720*1380 |
1123*900*1605 |
Packing Size(L*W*Hmm) |
980*825*1560 |
1185*960*1750 |
N.W.(kg) |
512 |
592 |
612 |
612 |
642 |
705 |
755 |
G.W.(kg)(Wooden Packing) |
552 |
632 |
652 |
652 |
692 |
755 |
805 |
INPUT |
DC Input Voltage Range |
10.5VDC-15VDC(Single battery voltage) |
AC Input Voltage Range |
380Vac/400Vac±10%(customized 190Vac/200Vac) |
AC Input Frequency Range |
45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz) |
Max AC charging current |
0-45A(Depending on the model) |
AC charging method |
Three-stage (constant current, constant voltage, floating charge) |
Phase |
3 PHASE |
OUTPUT |
Efficiency(Battery Mode) |
≥85% |
Output Voltage(Battery Mode) |
380Vac/400Vac±10%(customized 190Vac/200Vac) |
Output Frequency(Battery Mode) |
50/60Hz ±1% |
Output Wave(Battery Mode) |
Pure Sine Wave |
Output waveform distortion |
Linear load≤3% |
Efficiency(AC Mode) |
>99% |
Output Voltage(AC Mode) |
Conforming to AC input |
Output Frequency(AC Mode) |
Conforming to AC input |
No load loss(Battery Mode) |
≤1% rated power |
No load loss(AC Mode) |
≤2%rated power( charger does not work in AC mode) |
No load loss
(Energy saving Mode) |
≤10W |
Phase |
3 PHASE |
BATTERY |
VRLA Battery |
Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage) |
Customize battery |
Charging and discharging parameters of different types of batteries can be customized according to user requirements |
(charging and discharging parameters of different types of batteries can be set through the operation panel) |
Protection |
Battery undervoltage alarm |
11V(Single battery voltage) |
Battery undervoltage protection |
10.5V(Single battery voltage) |
Battery overvoltage alarm |
15V(Single battery voltage) |
Battery overvoltage protection |
17V(Single battery voltage) |
Battery overvoltage recovery voltage |
14.5V(Single battery voltage) |
Overload power protection |
Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
Inverter output short circuit protection |
Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
Temperature protection |
>90°C(Shut down output) |
Alarm |
A |
Normal working condition, buzzer has no alarm sound |
B |
Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection |
C |
When the machine is turned on for the first time, the buzzer will prompt 5
when the machine is normal |
Inside Solar controller |
Charging Mode |
MPPT or PWM |
(Optional) |
Charging current |
PWM: 100A-200A / MPPT: 50A/100A |
|
PV Input Voltage Range |
PWM: 480V-704V / MPPT: 480V-640V |
|
Max PV Input Voltage(Voc) |
PWM: 750V / MPPT: 800V |
|
(At the lowest temperature) |
|
PV Array Maximum Power |
PWM: 44.8KW(100A)/33.6KW*2(150A)/44.8KW*2(200A)) / (MPPT: 22.4KW(50A)/22.4KW*2(100A) |
|
Standby loss |
≤3W |
|
Maximum conversion efficiency |
>95% |
Working Mode |
Battery First/AC First/Saving Energy Mode |
Transfer Time |
≤4ms |
Display |
LCD |
Thermal method |
Forced Air Cooling |
Communication(Optional) |
RS485/APP(WIFI monitoring or GPRS monitoring) |
Environment |
Operating temperature |
-10℃~40℃ |
Storage temperature |
-15℃~60℃ |
Noise |
2000m(More than derating) |
Elevation |
≤65dB |
Humidity |
0%~95% ,No condensation |
*Product specifications are subject to change without further notice |